Description:
- Natural or LP
- Regulator setting: LO 1.5"-HI 3.5"
- LP conversion kit included
- Flow direction: str.thru
- For use with non-piloted intermittent ignition systems Inlet and outlet screens
- Quiet redundant
- Built-in pressure tap
- Quick connect terminals
BtuH Capacity: 100,000; Description: LP kit included; Inlet Conn.: 1/2"; Mfg. #: 36J54-214; Opening Style: Fast 2-Stage; Outlet Conn.: 1/2"; Side Tap: Yes; Volts: 24;
Specifications:
Regulator adjustment range: 2.5" to 5" W.C., LP gas 7" to 12" W.C., 4" to 9.5" W.C on L41-800, L41-801 and L41-972 |Ambient temperature rating: -40°F to +175°F |Includes reducer bushings kit, except L44-645 and L44-648