Description:
- Combines gas flow control and electronic sequencing functions in a single unit
- For direct replacement of OEM installations
- Inlet and outlet pressure tap accessible through top of unit
- Low voltage hot surface element lights pilot quickly
- Flame rectification proves pilot flame before main gas flows
- Appliance automatically resets after gas or power outage
- L41-674 is designed for use in LP applications only
Application: Direct Ignition; Includes: LP Conversion Kit; Mfg. #: SV9520H8513; Opening Style: Fast-Slow; Temp. Range: 0°F to +175°F;
Specifications:
Size: 1/2" inlet x 1/2" outlet |Ignitor warm-up time: 5 seconds (nominal) |Voltage and frequency: 24VAC, 50/60 Hz |System transformer: 40VA minimum, NEMA rated |Thermostat current: 0.2A